The Motor Modules communicate with the higher-level control module via DRIVE-CLiQ. This control module can be:

  • A CU320-2 Control Unit
  • A SIMOTION D Control Unit
  • A SINUMERIK 840D sl with NCU 710.3B PN/NCU 720.3B PN/NCU 730.3B PN
  • A SINAMICS NX10.3/NX15.3

Connection example of a Motor Module

技术规范

General technical specifications

Electrical specifications

Efficiency

>98.5 %

DC link voltage

(up to 2000 m (6562 ft) above sea level)

510 ... 720 V DC (line voltage 380 ... 480 V 3 AC) or
675 ... 1035 V DC (line voltage 500 ... 690 V 3 AC)

Output frequency 1)

 

  • Control type Servo

0 ... 550 Hz

  • Control type Vector

0 ... 550 Hz

  • Control mode V/f

0 ... 550 Hz

Safety Integrated

Safety Integrity Level 2 (SIL2) acc. to IEC 61508, Performance Level d (PLd) acc. to EN ISO 13849-1 and Control Category 3 acc. to EN ISO 13849‑1



1) Please note:

• The correlation between the maximum output frequency, pulse frequency and current derating. Higher output frequencies on request. For further information, see https://support.industry.siemens.com/cs/document/104020669

• The correlation between the minimum output frequency and permissible output current (current derating). Information is provided in the SINAMICS Low Voltage Engineering Manual.

Line voltage 380 ... 480 V 3 AC
DC link voltage 510 ... 720 V DC

Motor Modules

 

6SL3320-1TE32-1AA3

6SL3320-1TE32-6AA3

6SL3320-1TE33-1AA3

6SL3320-1TE33-8AA3

6SL3320-1TE35-0AA3

Type rating

 

 

 

 

 

 

  • At IL (50 Hz 400 V) 1)

kW

110

132

160

200

250

  • At IH (50 Hz 400 V) 1)

kW

90

110

132

160

200

  • At IL (60 Hz 460 V) 2)

hp

150

200

250

300

400

  • At IH (60 Hz 460 V) 2)

hp

150

200

200

250

350

Output current

 

 

 

 

 

 

  • Rated current Irated O

A

210

260

310

380

490

  • base-load current I3)

A

205

250

302

370

477

  • base-load current I4)

A

178

233

277

340

438

  • Maximum current Imax O

A

307

375

453

555

715

DC link current

 

 

 

 

 

 

  • Rated current Irated DC
    when supplied via

 

 

 

 

 

 

  • Basic/Smart Line Module

A

252

312

372

456

588

  • Active Line Module

A

227

281

335

411

529

  • base-load current IL DC 3)
    when supplied via

 

 

 

 

 

 

  • Basic/Smart Line Module

A

245

304

362

444

573

  • Active Line Module

A

221

273

326

400

515

  • base-load current IH DC 4)
    when supplied via

 

 

 

 

 

 

  • Basic/Smart Line Module

A

224

277

331

405

523

  • Active Line Module

A

202

250

298

365

470

Current demand

 

 

 

 

 

 

  • 24 V DC auxiliary power supply

A

0.8

0.8

0.9

0.9

0.9

  • 400 V AC

A

0.63

1.13

1.8

1.8

1.8

DC link capacitance

μF

4200

5200

6300

7800

9600

Pulse frequency 5)

 

 

 

 

 

 

  • Rated frequency

kHz

2

2

2

2

2

  • Pulse frequency, max.

 

 

 

 

 

 

  • Without current derating

kHz

2

2

2

2

2

  • With current derating

kHz

8

8

8

8

8

Power loss, max. 6)

 

 

 

 

 

 

  • At 50 Hz 400 V

kW

1.86

2.5

2.96

3.67

4.28

  • At 60 Hz 460 V

kW

1.94

2.6

3.1

3.8

4.5

Cooling air requirement

m3/s (ft3/s)

0.17 (6.00)

0.23 (8.12)

0.36 (12.7)

0.36 (12.7)

0.36 (12.7)

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

64/67

71/71

69/73

69/73

69/73

DC link connection

DCP, DCN

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 185

2 × 185

2 × 240

2 × 240

2 × 240

Connection for Braking Module

DCPA, DCNA 7)

 

M6 threaded bolt

M6 threaded bolt

M6 threaded bolt

M6 threaded bolt

M6 threaded bolt

Connection for dv/dt filter

DCPS, DCNS

 

M8 screw

M8 screw

M8 screw

M8 screw

M8 screw

  • Conductor cross-section, max. (IEC)

mm2

1 × 35

1 × 35

1 × 70

1 × 70

1 × 70

Motor connection

U2, V2, W2

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 185

2 × 185

2 × 240

2 × 240

2 × 240

Cable length, max. 8)

 

 

 

 

 

 

  • Shielded

m (ft)

300 (984)

300 (984)

300 (984)

300 (984)

300 (984)

  • Unshielded

m (ft)

450 (1476)

450 (1476)

450 (1476)

450 (1476)

450 (1476)

PE1/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 185

2 × 185

2 × 240

2 × 240

2 × 240

PE2/GND connection

 

M10 screw

M10 screw

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 185

2 × 185

2 × 240

2 × 240

2 × 240

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

326 (12.8)

326 (12.8)

326 (12.8)

326 (12.8)

326 (12.8)

  • Height

mm (in)

1400 (55.1)

1400 (55.1)

1533 (60.4)

1533 (60.4)

1533 (60.4)

  • Depth

mm (in)

356 (14.0)

356 (14.0)

545 (21.5)

545 (21.5)

545 (21.5)

Weight, approx.

kg (lb)

95 (209)

95 (209)

136 (300)

136 (300)

136 (300)

Frame size

 

FX

FX

GX

GX

GX



1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 400 V 3 AC 50 Hz.

2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 460 V 3 AC 60 Hz.

3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5) Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual .

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) The connecting cables are included in the scope of supply of the Braking Module.

8) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 380 ... 480 V 3 AC
DC link voltage 510 ... 720 V DC

Motor Modules

 

6SL3320-1TE36-1AA3

6SL3320-1TE37-5AA3

6SL3320-1TE38-4AA3

Type rating

 

 

 

 

  • At IL (50 Hz 400 V) 1)

kW

315

400

450

  • At IH (50 Hz 400 V) 1)

kW

250

315

400

  • At IL (60 Hz 460 V) 2)

hp

500

600

700

  • At IH (60 Hz 460 V) 2)

hp

350

450

600

Output current

 

 

 

 

  • Rated current Irated O

A

605

745

840

  • base-load current I3)

A

590

725

820

  • base-load current I4)

A

460

570

700

  • Maximum current Imax O

A

885

1087

1230

DC link current

 

 

 

 

  • Rated current Irated DC
    when supplied via

 

 

 

 

  • Basic/Smart Line Module

A

726

894

1008

  • Active Line Module

A

653

805

907

  • base-load current IL DC 3)
    when supplied via

 

 

 

 

  • Basic/Smart Line Module

A

707

871

982

  • Active Line Module

A

636

784

884

  • base-load current IH DC 4)
    when supplied via

 

 

 

 

  • Basic/Smart Line Module

A

646

795

897

  • Active Line Module

A

581

716

807

Current demand

 

 

 

 

  • 24 V DC auxiliary power supply

A

1.0

1.0

1.0

  • 400 V AC

A

3.6

3.6

3.6

DC link capacitance

μF

12600

15600

16800

Pulse frequency 5)

 

 

 

 

  • Rated frequency

kHz

1.25

1.25

1.25

  • Pulse frequency, max.

 

 

 

 

  • Without current derating

kHz

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

Power loss, max. 6)

 

 

 

 

  • At 50 Hz 400 V

kW

5.84

6.68

7.15

  • At 60 Hz 460 V

kW

6.3

7.3

7.8

Cooling air requirement

m3/s (ft3/s)

0.78 (27.5)

0.78 (27.5)

0.78 (27.5)

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

70/73

70/73

70/73

DC link connection

DCP, DCN

 

4 × hole for M10
Busbar

4 × hole for M10
Busbar

4 × hole for M10
Busbar

Connection for Braking Module

DCPA, DCNA 7)

 

Connection for connection clip

Connection for connection clip

Connection for connection clip

Connection for dv/dt filter

DCPS, DCNS

 

M10 screw

M10 screw

M10 screw

  • Conductor cross-section, max. (IEC)

mm2

1 × 185

1 × 185

1 × 185

Motor connection

U2, V2, W2

 

2 × M12 screw

2 × M12 screw

2 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

4 × 240

4 × 240

4 × 240

Cable length, max. 8)

 

 

 

 

  • Shielded

m (ft)

300 (984)

300 (984)

300 (984)

  • Unshielded

m (ft)

450 (1476)

450 (1476)

450 (1476)

PE1/GND connection

 

M12 screw

M12 screw

M12 screw

  • Conductor cross-section, max. (IEC)

mm2

240

240

240

PE2/GND connection

 

2 × M12 screw

2 × M12 screw

2 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

Degree of protection

 

IP00

IP00

IP00

Dimensions

 

 

 

 

  • Width

mm (in)

503 (19.8)

503 (19.8)

503 (19.8)

  • Height

mm (in)

1475 (58.1)

1475 (58.1)

1475 (58.1)

  • Depth

mm (in)

547 (21.5)

547 (21.5)

547 (21.5)

Weight, approx.

kg (lb)

290 (639)

290 (639)

290 (639)

Frame size

 

HX

HX

HX



1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 400 V 3 AC 50 Hz.

2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 460 V 3 AC 60 Hz.

3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5) Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual .

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) The connecting cables are included in the scope of supply of the Braking Module.

8) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.


免责声明:当前页为 6SL3352-6TG32-6AA3 DC675V-1080V 260A 西门子变频器 S120 CIB板产品信息展示页,该页所展示的 6SL3352-6TG32-6AA3 DC675V-1080V 260A 西门子变频器 S120 CIB板产品信息及价格等相关信息均有企业自行发布与提供, 6SL3352-6TG32-6AA3 DC675V-1080V 260A 西门子变频器 S120 CIB板产品真实性、准确性、合法性由店铺所有企业完全负责。世界工厂网对此不承担任何保证责任,亦不涉及用户间因交易而产生的法律关系及法律纠纷,纠纷由会员自行协商解决。

友情提醒:世界工厂网仅作为用户寻找交易对象,就货物和服务的交易进行协商,以及获取各类与贸易相关的服务信息的渠道。为避免产生购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量。过低的价格、夸张的描述、私人银行账户等都有可能是虚假信息,请您谨慎对待,谨防欺诈,对于任何付款行为请您慎重抉择。

投诉方式:fawu@gongchang.com是处理侵权投诉的专用邮箱,在您的合法权益受到侵害时,请将您真实身份信息及受到侵权的初步证据发送到该邮箱,我们会在5个工作日内给您答复,感谢您对世界工厂网的关注与支持!

上海幕炎工控设备有限公司
进入店铺
2014成立时间
联系方式 企业档案

电话01267897675

手机17821363396

微信17821363396

QQ1363502649

工商信息
统一社会信用代码91310116320890815M
成立日期2014年11月13日
组织机构代码320890815
经营状态存续
法定代表人方祖林
店铺推荐
全部产品
更新时间:2020-05-09
首页 分类 世界工厂 我的 客服
产品属性
加工定制
型号
6SL3352-6TG32-6AA3
用途
CIB板
提供加工定制
工作电压
23
输出频率
34
产品认证
is9001
品牌
西门子
功能
380
关闭
功能直达
首页
产品二维码
搜索
消息
全站同款
意见反馈
用小程序访问该企业,关注及对接
点击保存二维码,微信扫一扫识别
全部分类
工业品
原材料
消费品
智能制造
人工智能
双碳
新能源汽车
农业畜牧
宠物园艺
商务服务