6SL3352-6TG32-2AA3 DC675V-1080V 215A 西门子变频器 S120 CIB板
9500.00/个
上海
最小起订≥1个
供货总量9000个
发货期限1天
有效期长期有效
产品详情推荐
产品属性
加工定制
型号
6SL3352-6TG32-2AA3
用途
cib板
提供加工定制
工作电压
138
所有参数

联系电话:17821363396(微信同步)

联系人:蔡思锦

工作QQ:1363502649

上海幕炎工控设备有限公司



1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 500 V or 690 V 3 AC 50 Hz.

2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz.

3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5) Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual .

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) The connecting cables are included in the scope of supply of the Braking Module.

8) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 500 ... 690 V 3 AC
DC link voltage 675 ... 1035 V DC

Motor Modules

 

6SL3320-1TG34-1AA3

6SL3320-1TG34-7AA3

6SL3320-1TG35-8AA3

6SL3320-1TG37-4AA3

Type rating

 

 

 

 

 

  • At IL (50 Hz 690 V) 1)

kW

400

450

560

710

  • At IH (50 Hz 690 V) 1)

kW

315

400

450

630

  • At IL (50 Hz 500 V) 1)

kW

250

315

400

500

  • At IH (50 Hz 500 V) 1)

kW

200

250

315

450

  • At IL (60 Hz 575 V) 2)

hp

400

450

600

700

  • At IH (60 Hz 575 V) 2)

hp

350

450

500

700

Output current

 

 

 

 

 

  • Rated current Irated O

A

410

465

575

735

  • base-load current I3)

A

400

452

560

710

  • base-load current I4)

A

367

416

514

657

  • Maximum current Imax O

A

600

678

840

1065

DC link current

 

 

 

 

 

  • Rated current Irated DC
    when supplied via

 

 

 

 

 

  • Basic/Smart Line Module

A

492

558

690

882

  • Active Line Module

A

443

502

621

794

  • base-load current IL DC 3)
    when supplied via

 

 

 

 

 

  • Basic/Smart Line Module

A

479

544

672

859

  • Active Line Module

A

431

489

605

774

  • base-load current IH DC 4)
    when supplied via

 

 

 

 

 

  • Basic/Smart Line Module

A

437

496

614

784

  • Active Line Module

A

394

446

552

706

Current demand

 

 

 

 

 

  • 24 V DC auxiliary power supply

A

1.0

1.0

1.0

1.25

  • 500 V AC

A

3.0

3.0

3.0

4.4

  • 690 V AC

A

2.1

2.1

2.1

3.1

DC link capacitance

μF

7400

7400

7400

11100

Pulse frequency 5)

 

 

 

 

 

  • Rated frequency

kHz

1.25

1.25

1.25

1.25

  • Pulse frequency, max.

 

 

 

 

 

  • Without current derating

kHz

1.25

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

7.5

Power loss, max. 6)

 

 

 

 

 

  • At 50 Hz 690 V

kW

6.13

6.80

10.3

10.9

  • At 60 Hz 575 V

kW

5.71

6.32

9.7

10

Cooling air requirement

m3/s (ft3/s)

0.78 (27.5)

0.78 (27.5)

0.78 (27.5)

1.08 (38.1)

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

70/73

70/73

70/73

71/73

DC link connection

DCP, DCN

 

4 × hole for M10
Busbar

4 × hole for M10
Busbar

4 × hole for M10
Busbar

4 × hole for M10
Busbar

Connection for Braking Module

DCPA, DCNA 7)

 

M8 stud

M8 stud

M8 stud

M8 stud

Connection for dv/dt filter

DCPS, DCNS

 

M10 screw

M10 screw

M10 screw

2 x M10 screw

  • Conductor cross-section, max. (IEC)

mm2

1 × 185

1 × 185

1 × 185

2 × 185

Motor connection

U2, V2, W2

 

2 × M12 screw

2 × M12 screw

2 × M12 screw

3 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

4 × 240

4 × 240

4 × 240

6 × 240

Cable length, max. 8)

 

 

 

 

 

  • Shielded

m (ft)

300 (984)

300 (984)

300 (984)

300 (984)

  • Unshielded

m (ft)

450 (1476)

450 (1476)

450 (1476)

450 (1476)

PE1/GND connection

 

M12 screw

M12 screw

M12 screw

M12 screw

  • Conductor cross-section, max. (IEC)

mm2

240

240

240

240

PE2/GND connection

 

2 × M12 screw

2 × M12 screw

2 × M12 screw

3 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 240

2 × 240

2 × 240

3 × 240

Degree of protection

 

IP00

IP00

IP00

IP00

Dimensions

 

 

 

 

 

  • Width

mm (in)

503 (19.8)

503 (19.8)

503 (19.8)

704 (27.7)

  • Height

mm (in)

1475 (58.1)

1475 (58.1)

1475 (58.1)

1475 (58.1)

  • Depth

mm (in)

547 (21.5)

547 (21.5)

547 (21.5)

550 (21.7)

Weight, approx.

kg (lb)

290 (639)

290 (639)

290 (639)

450 (992)

Frame size

 

HX

HX

HX

JX



1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 500 V or 690 V 3 AC 50 Hz.

2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz.

3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5) Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual .

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) The connecting cables are included in the scope of supply of the Braking Module.

8) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.

Line voltage 500 ... 690 V 3 AC
DC link voltage 675 ... 1035 V DC

Motor Modules

 

6SL3320-1TG38-1AA3

6SL3320-1TG38-8AA3

6SL3320-1TG41-0AA3

6SL3320-1TG41-3AA3

Type rating

 

 

 

 

 

  • At IL (50 Hz 690 V) 1)

kW

800

900

1000

1200

  • At IH (50 Hz 690 V) 1)

kW

710

800

900

1000

  • At IL (50 Hz 500 V) 1)

kW

560

630

710

900

  • At IH (50 Hz 500 V) 1)

kW

500

560

630

800

  • At IL (60 Hz 575 V) 2)

hp

800

900

1000

1250

  • At IH (60 Hz 575 V) 2)

hp

700

800

900

1000

Output current

 

 

 

 

 

  • Rated current Irated O

A

810

910

1025

1270

  • base-load current I3)

A

790

880

1000

1230

  • base-load current I4)

A

724

814

917

1136

  • Maximum current Imax O

A

1185

1320

1500

1845

DC link current

 

 

 

 

 

  • Rated current Irated DC
    when supplied via

 

 

 

 

 

  • Basic/Smart Line Module

A

972

1092

1230

1524

  • Active Line Module

A

875

983

1107

1372

  • base-load current IL DC 3)
    when supplied via

 

 

 

 

 

  • Basic/Smart Line Module

A

947

1064

1199

1485

  • Active Line Module

A

853

958

1079

1337

  • base-load current IH DC 4)
    when supplied via

 

 

 

 

 

  • Basic/Smart Line Module

A

865

971

1094

1356

  • Active Line Module

A

778

874

985

1221

Current demand

 

 

 

 

 

  • 24 V DC auxiliary power supply

A

1.25

1.4

1.4

1.4

  • 500 V AC

A

4.4

4.4

4.4

4.4

  • 690 V AC

A

3.1

3.1

3.1

3.1

DC link capacitance

μF

11100

14400

14400

19200

Pulse frequency 5)

 

 

 

 

 

  • Rated frequency

kHz

1.25

1.25

1.25

1.25

  • Pulse frequency, max.

 

 

 

 

 

  • Without current derating

kHz

1.25

1.25

1.25

1.25

  • With current derating

kHz

7.5

7.5

7.5

7.5

Power loss, max. 6)

 

 

 

 

 

  • At 50 Hz 690 V

kW

11.5

11.7

13.2

16.0

  • At 60 Hz 575 V

kW

10.5

10.6

12.0

14.2

Cooling air requirement

m3/s (ft3/s)

1.08 (38.1)

1.08 (38.1)

1.08 (38.1)

1.08 (38.1)

Sound pressure level LpA

(1 m) at 50/60 Hz

dB

71/73

71/73

71/73

71/73

DC link connection

DCP, DCN

 

4 × hole for M10
Busbar

4 × hole for M10
Busbar

4 × hole for M10
Busbar

4 × hole for M10
Busbar

Connection for Braking Module

DCPA, DCNA 7)

 

M8 stud

M8 stud

M8 stud

M8 stud

Connection for dv/dt filter

DCPS, DCNS

 

2 x M10 screw

2 x M10 screw

2 x M10 screw

2 x M10 screw

  • Conductor cross-section, max. (IEC)

mm2

2 × 185

2 × 185

2 × 185

2 × 185

Motor connection

U2, V2, W2

 

3 × M12 screw

3 × M12 screw

3 × M12 screw

3 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

6 × 240

6 × 240

6 × 240

6 × 240

Cable length, max. 8)

 

 

 

 

 

  • Shielded

m (ft)

300 (984)

300 (984)

300 (984)

300 (984)

  • Unshielded

m (ft)

450 (1476)

450 (1476)

450 (1476)

450 (1476)

PE1/GND connection

 

M12 screw

M12 screw

M12 screw

M12 screw

  • Conductor cross-section, max. (IEC)

mm2

240

240

240

240

PE2/GND connection

 

3 × M12 screw

3 × M12 screw

3 × M12 screw

3 × M12 screw

  • Conductor cross-section, max. (IEC)

mm2

3 × 240

3 × 240

3 × 240

3 × 240

Degree of protection

 

IP00

IP00

IP00

IP00

Dimensions

 

 

 

 

 

  • Width

mm (in)

704 (27.7)

704 (27.7)

704 (27.7)

704 (27.7)

  • Height

mm (in)

1475 (58.1)

1475 (58.1)

1475 (58.1)

1475 (58.1)

  • Depth

mm (in)

550 (21.7)

550 (21.7)

550 (21.7)

550 (21.7)

Weight, approx.

kg (lb)

450 (992)

450 (992)

450 (992)

450 (992)

Frame size

 

JX

JX

JX

JX



1) Rated output of a typical 6-pole standard induction motor based on IL or IH for 500 V or 690 V 3 AC 50 Hz.

2) Rated output of a typical 6-pole standard induction motor based on IL or IH for 575 V 3 AC 60 Hz.

3) The base-load current IL is based on a duty cycle of 110 % for 60 s or 150 % for 10 s with a duty cycle duration of 300 s.

4) The base-load current IH is based on a duty cycle of 150 % for 60 s or 160 % for 10 s with a duty cycle duration of 300 s.

5) Information regarding the correlation between the pulse frequency and maximum output current/output frequency is provided in the SINAMICS Low Voltage Engineering Manual .

6) The specified power loss represents the maximum value at 100 % utilization. The value is lower under normal operating conditions.

7) The connecting cables are included in the scope of supply of the Braking Module.

8) Total of all motor cables and DC link. Longer cable lengths for specific configurations are available on request. For additional information, please refer to the SINAMICS Low Voltage Engineering Manual.


全部关于 Motor Modules
产品与解决方案在线目录与订购系统技术信息服务与支持联系人与合作伙伴服务项目


免责声明:当前页为 6SL3352-6TG32-2AA3 DC675V-1080V 215A 西门子变频器 S120 CIB板产品信息展示页,该页所展示的 6SL3352-6TG32-2AA3 DC675V-1080V 215A 西门子变频器 S120 CIB板产品信息及价格等相关信息均有企业自行发布与提供, 6SL3352-6TG32-2AA3 DC675V-1080V 215A 西门子变频器 S120 CIB板产品真实性、准确性、合法性由店铺所有企业完全负责。世界工厂网对此不承担任何保证责任,亦不涉及用户间因交易而产生的法律关系及法律纠纷,纠纷由会员自行协商解决。

友情提醒:世界工厂网仅作为用户寻找交易对象,就货物和服务的交易进行协商,以及获取各类与贸易相关的服务信息的渠道。为避免产生购买风险,建议您在购买相关产品前务必确认供应商资质及产品质量。过低的价格、夸张的描述、私人银行账户等都有可能是虚假信息,请您谨慎对待,谨防欺诈,对于任何付款行为请您慎重抉择。

投诉方式:fawu@gongchang.com是处理侵权投诉的专用邮箱,在您的合法权益受到侵害时,请将您真实身份信息及受到侵权的初步证据发送到该邮箱,我们会在5个工作日内给您答复,感谢您对世界工厂网的关注与支持!

上海幕炎工控设备有限公司
进入店铺
2014成立时间
联系方式 企业档案

电话01267897675

手机17821363396

微信17821363396

QQ1363502649

工商信息
统一社会信用代码91310116320890815M
成立日期2014年11月13日
组织机构代码320890815
经营状态存续
法定代表人方祖林
店铺推荐
全部产品
更新时间:2020-05-09
首页 分类 世界工厂 我的 客服
产品属性
加工定制
型号
6SL3352-6TG32-2AA3
用途
cib板
提供加工定制
工作电压
138
输出频率
22
产品认证
is9001
品牌
西门子
功能
380
关闭
功能直达
首页
产品二维码
搜索
消息
全站同款
意见反馈
用小程序访问该企业,关注及对接
点击保存二维码,微信扫一扫识别
全部分类
工业品
原材料
消费品
智能制造
人工智能
双碳
新能源汽车
农业畜牧
宠物园艺
商务服务