Microfluidic SP1.2 Platform
详细配置如下:
▲Microscope Axiovert 40 CFL :
Contrast option:Brightfield, Phase, Varel, Fluorescence (TRITC, FITC, etc).
Shutters:Automated Brightfield and Fluorescence.
Objectives:10x LD A-Plan, 20x LD A-Plan, 32x CP-Achromat, 40x LD A-Plan .
Eyepieces:E-PL 10x/20 Br., 10x/20 Br. foc.
Stage:Vena8 biochip compatible stage holder, Eppendorf tubes holder.
▲Mirus 1.0 Nanopump
Specifications:Shear Stress Range of 0.05–20 dyne/cm2, Volumetric Flow Rates 100nL–20μL/minute (100μL syringe), Sample Volume Increments Freely adjustable LinearVelocity Range of 10 μm/s to 10 cm/s; Flow Direction Reversible; Sample Volume Aspiration Accuracy ±1% ; Shear Stress Accuracy ±0.5%; Sample Volume Aspiration Precision < 1%.
Multichannel:16-Way manifold allowing individual addressing microchannels of Vena8 biochip.
▲Motorized stage with Z-focus module.
Specifications:Marzhauser IM series stage, Travel 120mm x100 mm, Repeatability <1um, Precision ±3 μm,Maximum Travel speed 180 mm/s.
▲Microscope Cage incubator:
Capabilities:Temperature control ± 0.10C, CO2 and humidity module.
Options:Temperature monitoring software module, black panels for use in fluorescent microscopy.
▲Deltapix DP 450 USB 2.0 camera
Specifications:2 Mega Pixels (1,616 x 1,216); Color CDD; 1/1.8" format; Pixel 4.4 μm x 4.4 μm.
Resolution:12 FPS @ 1,616 x 1,216 pixels; 14 FPS @ 1,280 x 1,024 pixels; 18 FPS @ 1,024 x 768 pixels; 22
FPS @ 800 x 600 pixels; 26 FPS @ 640 x 480 pixels. Dynamic Range > 66 dB.
▲Dell Optiplex 745 PC computer
Configuration:Intel Core2 processor; 1.86 GHz; 2GB RAM; ATI Radeon X1300PRO; Objective Imaging stage control hardware; 19” LCD monitor. Windows XP ProfessionalSP2; DeltaPix Viewer Software;VenaFluxAssay and DucoCell software preinstalled.
▲VenaFluxAssay Software.
Capabilities:Execution of preset protocols, simultaneous control of pumping, scanning and image acquisitions, sample transfer and protocol flow. Intuitivestepwise protocol interface with steps hierarchy and status control. Office2007 GUI interface, preset and user-designed protocols.
▲DucoCell software
Specifications:Automatic Counting and Detection;Morphological parameters analyzed automatically(Area, diameter, form-factor, ellipticity, eccentricity,orientation, perimeter, asymmetry, cell centroid coordinates, elliptical axis); Cell sorting and filtering; Ability to analyze sub-populations based on inclusion/exclusion of morphologicalparameters. Data may be exported to Excel spreadsheet incorporating automatic graph generation (e.g. % cell adhesion vs. shear stress). File Formats analyzed*.jpg, *.jpeg, *.tif, *.tiff, *.bmp,*.gif, *.png.
▲Vena8 biochips pack of 10
Specifications:Minimum Sample Volume 3 μL; Maximum Sample Volume 100 μL; Shear Stress Range of 0.05– 20 dyne/cm2, steps of 0.05dyne/cm2. Number of channels perbiochip is 8; Volume of each channel is 0.8μL. Dead volume at input port is 0.1 μL. Vena8 biochip dimensions are 400 μm (W) x 100 μm (D) x 20 mm(L).
免责声明:当前页为 细胞活性分析系MicrofluidicsSP1.2产品信息展示页,该页所展示的 细胞活性分析系MicrofluidicsSP1.2产品信息及价格等相关信息均有企业自行发布与提供, 细胞活性分析系MicrofluidicsSP1.2产品真实性、准确性、合法性由店铺所有企业完全负责。世界工厂网对此不承担任何保证责任,亦不涉及用户间因交易而产生的法律关系及法律纠纷,纠纷由会员自行协商解决。